Power cable CU MCMK Draka
CU-POWER CABLE MCMK 2X1,5/1,5 R100 ECA
DRAKA
With registration you can access the Würth Elektro online shop selection.
Datasheets(X)
Conductor material | Copper |
Conductor surface | Bare |
Nominal cross section conductor | 1.5 mm² |
AWG size | Other |
Conductor category | Class 1 = solid |
Conductor resistance at 20 °C | 12.1 Ohm/km |
Shape of conductor | Round |
Number of cores | 3 |
Material core insulation | Polyvinyl chloride (PVC) |
Specification core insulation | Other |
Core identification according to HD 308 S2 | Yes |
Core identification | Colour |
Laminated sheath | No |
Fibre optic elements | No |
With protective conductor | Yes |
Inner semi-conducting layer | No |
Outer semi-conducting layer | No |
Screen | No |
Drain wire | No |
Lead sheath | No |
Number of pilot/reduced conductors | 0 |
Nominal cross section pilot/reduced core | 0 mm² |
Concentric conductor | Copper |
Nominal cross section concentric conductor | 1.5 mm² |
Armouring | No |
Material outer sheath | Polyvinyl chloride (PVC) |
Specification material outer sheath | Other |
Colour outer sheath | Black |
Cable geometry | Round |
Conductive coating | No |
Longitudinal water blocking conductors | No |
Longitudinal water blocking screen | No |
Reaction-to-fire according to EN 13501-6: Class | Eca |
Reaction-to-fire according to EN 13501-6: Smoke production | None |
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles | None |
Reaction-to-fire according to EN 13501-6: Acidity | None |
Halogen free according to EN 60754-1/2 | No |
Halogen free according to EN IEC 60754-2 | No |
Flame retardant | According to IEC/EN 60332-1-2 |
Low smoke (according to EN 61034-2) | No |
Low smoke according to EN IEC 61034-2 | No |
Insulation integrity in accordance with IEC 60331 | No |
Insulation integrity | None |
Circuit integrity | None |
Oil resistant (acc. IEC 60811-404) | No |
Outer diameter approx. | 12 mm |
Min. permitted bending radius, stationary application/permanent installation | 145 mm |
Weight | 180 kg/km |
Max. conductor temperature | 70 °C |
Permitted cable outer temperature during assembling/handling | -15-40 °C |
Permitted cable outer temperature after assembling without vibration | -40-60 °C |
Nominal voltage U0 | 0.6 kV |
Nominal voltage U | 1 kV |
Suitable as installation cable | Yes |
Certified for shipboard application | No |
Suitable as medium-voltage cable | No |
Suitable as high-voltage cable | No |
Certified as airport lighting cable | No |