Conductor material | Copper |
Conductor surface | Bare |
Nominal cross section conductor | 2.5 mm² |
AWG size | Other |
Nominal cross section conductor (AWG) | 4.93 kcmil |
Diameter conductor | 1.78 mm |
Conductor category | Class 1 = solid |
Number of strands per conductor | 1 |
Strand diameter | 1.78 mm |
Conductor resistance at 20 °C | 7.41 Ohm/km |
Shape of conductor | Round |
Number of cores | 4 |
Material core insulation | Other |
Core identification according to HD 308 S2 | Yes |
Core identification | Colour |
Laminated sheath | No |
Fibre optic elements | No |
With protective conductor | No |
Inner semi-conducting layer | No |
Outer semi-conducting layer | No |
Screen | No |
Drain wire | No |
Lead sheath | No |
Protective barrier | None |
Armouring/reinforcement | None |
Radial water blocking cable | No |
Nominal cross section pilot/reduced conductors | 0 mm² |
Concentric conductor | Copper |
Nominal cross section concentric conductor | 2.5 mm² |
Material outer sheath | Other |
Colour outer sheath | Black |
Cable geometry | Round |
Halogen free according to EN 60754-1/2 | No |
Conductive coating | No |
Longitudinal water blocking conductors | No |
Flame retardant | According to IEC/EN 60332-1-2 |
Longitudinal water blocking screen | No |
Flame retardant according to IEC 60332-1-2 | No |
Flame retardant according to IEC 60332-3-21 (Cat A F/R) | No |
Flame retardant according to IEC 60332-3-22 (Cat A) | No |
Flame retardant according to IEC 60332-3-23 (Cat B) | No |
Flame retardant according to IEC 60332-3-24 (Cat C) | No |
Flame retardant according to IEC 60332-3-25 (Cat D) | No |
Low smoke according to EN IEC 61034-2 | No |
Halogen free according to EN IEC 60754-1 | No |
Halogen free according to EN IEC 60754-2 | No |
Halogen free according to EN IEC 60754-3 | No |
Reaction-to-fire according to EN 13501-6: Class | Eca |
Reaction-to-fire according to EN 13501-6: Smoke production | None |
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles | None |
Reaction-to-fire according to EN 13501-6: Acidity | None |
Circuit integrity according to IEC 60331-1 | None |
Circuit integrity according to IEC 60331-2 | None |
Circuit integrity according to IEC 60331-3 | None |
Circuit integrity according to EN 50200 | None |
Circuit integrity according to EN 50200 annex E | No |
Oil resistant according to EN IEC 60811-404 | No |
Cable width approximate | 13.1 mm |
Cable height approximate | 13.1 mm |
Outer diameter approximate | 13.1 mm |
Min. permitted bending radius, stationary application/permanent installation | 157.2 mm |
Weight | 251 kg/km |
Max. permitted conductor temperature | 70 °C |
Permitted cable outer temperature during assembling/handling | -10-40 °C |
Permitted cable outer temperature after assembling without vibration | -40-70 °C |
Nominal voltage U0 | 0.6 kV |
Nominal voltage U | 1 kV |
Nominal equivalent cross section of reinforcement | 0 mm² |
Suitable for underground installation | Yes |
Suitable as installation cable | Yes |
Certified for shipboard application | No |
Suitable as medium-voltage cable | No |
Suitable as high-voltage cable | No |
Certified as airport lighting cable | No |
With rodent protection | No |
Circuit integrity according to BS 6387 CWZ | No |
Circuit integrity according to BS 8434-2 | No |
Circuit integrity according to BS 8491 | No |
E-number Finland | 0614688 |