Power cable CU MCMK Prysmian
MCMK 4X150/70 AN 1kV Eca
PRYSMIAN
With registration you can access the Würth Elektro online shop selection.
For stationary installations indoors, outdoors, and to earth. Also for structures such as direct concrete casting.
Datasheets(X)
Conductor material | Copper |
Conductor surface | Bare |
Nominal cross section conductor | 150 mm² |
AWG size | Other |
Conductor category | Class 2 = stranded |
Conductor resistance at 20 °C | 0.124 Ohm/km |
Shape of conductor | Sector-shaped |
Number of cores | 5 |
Material core insulation | Polyvinyl chloride (PVC) |
Specification core insulation | Other |
Core identification according to HD 308 S2 | Yes |
Core identification | Colour |
Laminated sheath | No |
Fibre optic elements | No |
With protective conductor | Yes |
Inner semi-conducting layer | No |
Outer semi-conducting layer | No |
Screen | No |
Drain wire | No |
Lead sheath | No |
Number of pilot/reduced conductors | 0 |
Nominal cross section pilot/reduced core | 0 mm² |
Concentric conductor | Copper |
Nominal cross section concentric conductor | 70 mm² |
Armouring | No |
Material outer sheath | Polyvinyl chloride (PVC) |
Specification material outer sheath | Other |
Colour outer sheath | Black |
Cable geometry | Round |
Conductive coating | No |
Longitudinal water blocking conductors | No |
Longitudinal water blocking screen | No |
Reaction-to-fire according to EN 13501-6: Class | Eca |
Reaction-to-fire according to EN 13501-6: Smoke production | None |
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles | None |
Reaction-to-fire according to EN 13501-6: Acidity | None |
Halogen free according to EN 60754-1/2 | No |
Halogen free according to EN IEC 60754-2 | No |
Flame retardant | According to IEC/EN 60332-1-2 |
Low smoke (according to EN 61034-2) | No |
Low smoke according to EN IEC 61034-2 | No |
Insulation integrity in accordance with IEC 60331 | No |
Insulation integrity | None |
Circuit integrity | None |
Oil resistant (acc. IEC 60811-404) | No |
Outer diameter approx. | 48 mm |
Min. permitted bending radius, stationary application/permanent installation | 580 mm |
Weight | 7100 kg/km |
Max. conductor temperature | 70 °C |
Permitted cable outer temperature during assembling/handling | -15-40 °C |
Permitted cable outer temperature after assembling without vibration | -40-60 °C |
Nominal voltage U0 | 0.6 kV |
Nominal voltage U | 1 kV |
Suitable as installation cable | Yes |
Certified for shipboard application | No |
Suitable as medium-voltage cable | No |
Suitable as high-voltage cable | No |
Certified as airport lighting cable | No |