MOTOR STARTER ISL SIL CONNECTION
With registration you can access the Würth Elektro online shop selection.
18 month warranty
Datasheets(X)
![]() | |
Supply voltage DC | 20.4-28.8 V |
Voltage type (supply voltage) | DC |
Number of functions | 1 |
Number of HW-interfaces other | 2 |
With optical interface | No |
Supporting protocol for EtherCAT | No |
Supporting protocol for TCP/IP | No |
Supporting protocol for PROFIBUS | No |
Supporting protocol for CAN | No |
Supporting protocol for INTERBUS | No |
Supporting protocol for ASI | No |
Supporting protocol for KNX | No |
Supporting protocol for Modbus | No |
Supporting protocol for Data-Highway | No |
Supporting protocol for DeviceNet | No |
Supporting protocol for SUCONET | No |
Supporting protocol for LON | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFINET CBA | No |
Supporting protocol for SERCOS | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for INTERBUS-Safety | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Supporting protocol for other bus systems | Yes |
Radio standard Bluetooth | No |
Radio standard WLAN 802.11 | No |
Radio standard GPRS | No |
Radio standard GSM | No |
Mobile communications standard 3G (UMTS) | No |
IO link master | No |
System accessory | Yes |
Suitable for counting | No |
Suitable for weighing | No |
Suitable for temperature control | No |
Suitable for welding control | No |
Suitable for pressure control | No |
Suitable for NC | No |
Suitable for electronic positioning | No |
Suitable for CNC | No |
Suitable for SSI | No |
Suitable for incremental data detection | No |
Suitable for detection absolute value | No |
Suitable for flux controller | No |
Suitable for flux measurement | No |
Suitable for path controller | No |
Suitable for cam controller | No |
Suitable for flying saw | No |
Suitable for multi-axis control | No |
Suitable for single-axis controller | No |
Suitable for multi-axis positioning | No |
Suitable for single-axis positioning | No |
Function block restart blockage | No |
Function block automatic reset | No |
Contactor control function block | Yes |
Function block emergency stop | No |
Function block contactless working protection installation | No |
Function block affirm push button | No |
Function block 2-hand switching | No |
Function block operating mode selection | No |
Function block access control | No |
Degree of protection (IP) | IP20 |
Fieldbus connection over separate bus coupler possible | Yes |
Frequency measurement | No |
Suitable for rail mounting | Yes |
Wall mounting/direct mounting | No |
Front built-in possible | No |
Rack-assembly possible | No |
Suitable for safety functions | Yes |
SIL according to IEC 61508 | 2 |
Performance level according to EN ISO 13849-1 | Level d |
Appendant operation agent (Ex ia) | No |
Appendant operation agent (Ex ib) | No |
Explosion safety category for gas | None |
Explosion safety category for dust | None |
Certified for UL hazardous location class I | No |
Certified for UL hazardous location class II | No |
Certified for UL hazardous location class III | No |
Certified for UL hazardous location division 1 | No |
Certified for UL hazardous location division 2 | No |
Certified for UL hazardous location group A (acetylene) | No |
Certified for UL hazardous location group B (hydrogen) | No |
Certified for UL hazardous location group C (ethylene) | No |
Certified for UL hazardous location group D (propane) | No |
Certified for UL hazardous location group E (metal dusts) | No |
Certified for UL hazardous location group F (carbonaceous dusts) | No |
Certified for UL hazardous location group G (non-conductive dusts) | No |
Width | 25 mm |
Height | 118 mm |
Depth | 114 mm |
E-number Finland | 3781775 |